Engineering Appraisal of SwRI Magnetic Crack Definer Applied to CH-47 Rotor Blades: Verification Addendum.

Abstract

This addendum effort evaluates the Magnetic Crack Definer (MCD) and an ultrasonics system on CH-47 helicopter rotor blade spars to determine the capabilities for detecting fatigue cracks under the ferromagnetic steel doubler plates and to determine possible sources of false alarms. Although attempts to adapt the MCD to doubler plates were unsuccessful, a supplementary ultrasonics procedure developed during the program can inspect all spar material in the doubler regions. The remaining outboard regions were inaccessible to ultrasonics due to overlaying materials. These outboard regions are accessible, however, to the MCD which accommodates as much as 0.1 inch of lift-off due to nonferromagnetic overlays. (Modified author abstract)

Document Details

Document Type
Technical Report
Publication Date
May 01, 1974
Accession Number