Improved Aqua-Lung Regulator Model DW.

Abstract

The report covers the evaluation of the Improved Aqua-Lung Regulator Model DW to determine the suitability of the apparatus for use in the Naval service to depths of 200 feet at work rates equivalent to 0.85-knot swimming. The report describes the demand regulator in detail. The regulator was tested objectively by breathing machine and subjectively by depth runs with instrumentation for respiratory pressure, respiratory minute volume, and breathing rate. It was also tested subjectively by swimming pool runs with open-circuit scuba. Breathing machine and subjective depth runs are summarized as graphs of peak respiratory pressure, RMV, and RR against time. Subjective swimming test results are summarized narratively. (Modified author abstract)

Document Details

Document Type
Technical Report
Publication Date
Jan 31, 1956
Accession Number
AD0782763

Entities

People

  • W. C. Hollingsworth

Organizations

  • United States Navy Experimental Diving Unit

Tags

DTIC Thesaurus Topics

  • Abstracts
  • Instrumentation
  • Measuring Instruments
  • Regulators
  • Respiration
  • Swimming
  • Test And Evaluation

Readers

  • Aerospace Test and Evaluation
  • Atmospheric Science/Meteorology
  • Marine Mammal Biology