The report describes a transportable membrane separator-mass spectrometer system for the detection of trace vapors in ambient atmosphere. It employs a Llewellyn membrane separator, a quadrupole mass filter, and an on line system for data processing and display. Design electronics, and software are discussed, and installations in a mobile van and a fixed-wing aircraft are described.