Installation of a Rectangular Test Section for Acoustic Water Tunnel Studies of Flow-Induced Noise,
Abstract
A second leg was added to an existing pump driven, continuous flow, closed loop acoustic water tunnel to provide a capability for measuring flow-induced noise effects and the effects of surface roughness, protuberances, depressions, and pressure gradients on turbulent boundary layer wall-pressure fluctuations. The leg consists of a rectangular test section 4 inches high at the entrance and 4.5 inches high at the exit, with a constant width of 12 inches over a length of 90 inches. The report describes the design and construction of the new section and related components and the results of hydrodynamic and acoustic measurements. (Modified author abstract)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 21, 1974
- Accession Number
- AD0786693
Entities
People
- Howard H. Schloemer
Organizations
- Naval Underwater Systems Center