Flow Regimes in Two-Dimensional Ribbed Diffusers.

Abstract

Water table flow visualization tests of a straight wall diffuser and corresponding ribbed diffuser were conducted over a wide range of total divergence angles and diffuser length to throat width ratios. Rib parameters such as inter-rib cavity depth to width ratio, inter-rib cavity width, rib thickness and number of ribs were varied, as well as rib contour. Motion pictures were obtained of the secondary flow patterns occurring within the inter-rib cavities, and hot film measurements were made to determine the extent of velocity fluctuations induced by the cavities. In general, the addition of ribs increased the no-appreciable stall regime by increasing velocity fluctuations near the wall of the diffuser, thereby promoting momentum exchange. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1974
Accession Number
AD0786887

Entities

People

  • Frank D. Stull

Organizations

  • Air Force Research Laboratory

Tags

DTIC Thesaurus Topics

  • Diffusers
  • Flow
  • Flow Visualization
  • Groundwater
  • Measurement
  • Momentum
  • Motion Pictures
  • Physical Properties
  • Secondary Flow
  • Thickness
  • Two Dimensional
  • Visualizations

Fields of Study

  • Physics

Readers

  • Combustion and Flow Dynamics.