Test of Low Discharge Type Storage Batteries.
Abstract
This report compares the performance of two types of low discharge batteries as regards shelf life, intermittent load, continuous duty at room temperature and continuous duty at elevated temperatures. The batteries compared employed different alloys in plate construction. The C and D battery used a calcium lead alloy, while the Willard cell made use of a high purity antimony lead. (Modified author abstract)
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 15, 1953
- Accession Number
- AD0787125
Entities
People
- John B. Oren