Differential Omega Test and Evaluation Program.

Abstract

Simultaneous OMEGA phase measurements were made with a reference monitor receiving system located at Austin, Texas, and with two mobile systems operating at various pairs of sites ranging from roughly 50 n. miles to 300 n. miles distance from Austin. Measurements commenced 20 October 1966 and continued through November. More than 750,000 independent phase readings of the received OMEGA signals from Trinidad, Haiku, and Forestport, at 10.2 kHz and 13.6 kHz frequencies, were recorded in digital form (to 0.1 centicycle resolution) on punched paper tape. Descriptive data on the instrumentation used in the OMEGA field monitoring program, methods of computer processing and data reduction, and a summary of results, data analysis and conclusions are discussed.

Document Details

Document Type
Technical Report
Publication Date
Jan 18, 1967
Accession Number
AD0787710

Entities

Organizations

  • Tracor

Tags

DTIC Thesaurus Topics

  • Computers
  • Data Analysis
  • Data Reduction
  • Frequency
  • Instrumentation
  • Measurement
  • Measuring Instruments
  • Monitoring
  • Phase
  • Phase Measurement
  • Test And Evaluation
  • Trinidad

Readers

  • Astronomy and Astrophysics.
  • Computer Science/Computer Engineering/Data Science/Digital Signal Processing.
  • Electromagnetic Wave Scattering and Antenna Radiation Engineering