PRODUCTION ENGINEERING MEASURE FOR IMPROVED RELIABILITY OF SOLID ELECTROLYTE TANTALUM CAPACITORS.
Abstract
The 85 C Proof Life Test continues. A total of 69.67 million unit hours of test has been accumulated with one failure. This represents an overall failure rate of 0.003 percent per 1000 hours at the 60 percent confidence level. (Author)