CONTRACT END ITEM DETAIL SPECIFICATION. PART II. PRODUCT CONFIGURATION AND ACCEPTANCE TEST REQUIREMENTS. AMPLIFIER-CONTROL GROUP OG-51(V)/UCC-4(V).
Abstract
The Amplifier Control Group monitors the 104.08 kHz group pilot and activates an alarm should the pilot level deviate 5 db from its normal level. It is also equipped with isolation amplifiers to improve the return loss. The Amplifier Control Group is equipped to monitor one 12-channel group.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 30, 1967
- Accession Number
- AD0818226