CALIBRATION OF ELBOW FLOW METER FOR LIQUID OXYGEN VENT SYSTEM,
Abstract
This report describes the flow calibration of the 6 3/8-inch oxidizer vent system for the RTS phase 3 missile. The vent system was calibrated with gaseous oxygen at flows ranging from 4 to 16 lb/sec. A flow equation for the vent system has been developed from the calibration data and is shown in the results. (Author)