RESULTS OF BOIL-OFF VALVE VIBRATION TESTS,
Abstract
The purpose of the report is to give the results of the liquid oxygen boil-off valve vibration test conducted on Missile 30D at the Point Loma test site. The report contains data on dynamic stresses in the forward bulkhead, tank and valve pressures, and deflections during boil-off valve vibration. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 19, 1960
- Accession Number
- AD0842202
Entities
People
- G. R. Rewerts
Organizations
- General Dynamics