Evaluation of Loads Induced in 'F' B1 LO2 Line Support CVA Dwg. No. 27-21001.
Abstract
The object was to measure loads induced in the LO2 duct support, versus differential pressure across the airborne LO2 fill/drain butterfly valve; and to prove the adequacy of two 3/8 inch high strength bolts to carry the load, and to substantiate airborne ducting and support integrity.