Strength Summary - Erector Boom - SM-65E,
Abstract
Critical margins of safety of the SM-65E erector boom are tabulated in this report. All detail parts possessing margins of safety of less than 15% are listed. Components are grouped primarily according to the major structural item to which they belong, and are sub-grouped according to their critical load condition. (Author)