Abstract
The design and status of equipment being assembled for a study of the high-temperature vaporization of graphite is presented. Involved is a versatile high-pressure sampling system coupled with a magnetic mass spectrometer. The first phase of studies having to do with the effect of cold sampling probes on hot gases will be carried out in the present Bendix mass spectrometer beam system. A time-of-flight scheme for measuring velocity distributions in supersonic beams is described together with a computer program to develop predicted behavior. A brief reference to discrepancies in presently published data on carbon is made and future plans discussed. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 22, 1968
- Accession Number
- AD0844686
Entities
People
- F. T. Greene
- T. A. Milne
Organizations
- MRIGlobal