High Power Ferrite Gas Duplexer.
Abstract
The report covers the high power testing of two Ferrite Gas Duplexers to date. The first unit was constructed with a Beryllium Oxide Loaded Epoxy and was run up to 60 Kw average before failure. The second unit, constructed with a Hysol Epoxy, was operated up to 100 Kw before severe arcing terminated the test. One unit has been reconstructed using a more elastic epoxy as the bonding material and has been submitted for test. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 31, 1969
- Accession Number
- AD0847370
Entities
People
- S. Segal
Organizations
- M/A-COM Technology Solutions