Electro-Interference Test Report for Figure A 9462, Amplifier/Converter Group. Volume 1,
Abstract
This document reports the results of the Electro-Interference test performed on the Amplifier/Converter Group. A test was made to determine its degree of compliance to AF/BSD Exhibit 62-87, Electro-Interference Control Requirements for Minuteman, as required by contract. The test was conducted in accordance with the requirements of D2-31414-1, Electro-Interference Test Plan for MOD 7/MOD 8/MM III Equipment, and with the detailed Electro-Interference test procedures document D2-18506-1. The test Item was connected to a simulator that simulated weapon system interfaces and permitted the Figure A to function in its operational modes while the generated interference measurements and susceptibility tests were made. The Test Item exceeded the test limits of AF/BSD Exhibit 62-87 for conducted and radiated generation. The Test Item was within the specifications of AF/BSD Exhibit 62-87 for the Antenna Conducted Tests and the Susceptibility Tests.