Operation and Service Manual for ECS Primary O2 System High Pressure Leak Rate Tester 52E180193.

Abstract

The purpose of the report is to familiarize personnel with the operation and service instructions for the Environmental Control System (ECS) Primary O2 System High Pressure Leak Rate Tester. The tester consists of two carrying cases and is used to determine spacecraft ECS leakages. The report presents a description of the tester, its control and indicator functions, and service instructions for preventive maintenance. (Author)

Document Details

Document Type
Technical Report
Publication Date
Dec 20, 1968
Accession Number
AD0857137

Entities

Organizations

  • McDonnell Douglas

Tags

Communities of Interest

  • Space

DTIC Thesaurus Topics

  • Control Systems
  • High Pressure
  • Indicators
  • Instructions
  • Maintenance
  • Maintenance Personnel
  • Preventive Maintenance

Readers

  • Logistics and Supply Chain Management.
  • Software Engineering
  • Tribology (the study of the boundary interaction between sliding surfaces, lubrication, wear and friction).

Technology Areas

  • Space
  • Space - Satellites