The Compatibility of VARIOUS Metals with MHF-3
Abstract
The compatibility of various pure metals with MHF-3 was determined at 74C (165F). Metals investigated included titanium, copper, iron, aluminum, and nickel in the annealed and cold-worked conditions, and chemically deposited chromium. Tests were conducted in an all pyrex, torch-sealed pressure vessel. Pressure changes were recorded over a 94 day period. Post exposure evaluations of the metals were made by electron microscopic examination, microprobe analysis, and tensile tests.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1970
- Accession Number
- AD0872299
Entities
People
- A. T. Robinson
- G. W. Burdette
Organizations
- Naval Air Weapons Station China Lake