Establishment of Cooling Air Requirements for Navigational Set TACAN AN/ARN-52(V).
Abstract
Required cooling airflow versus inlet air temperature curves (ambient temperature and altitude as parameters) were established for the TACAN AN/ARN-52(V) equipment. A static pressure drop versus airflow rate curve was determined. Equipment thermal design features are discussed and cooling blower sizing and selection procedures are included. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 30, 1970
- Accession Number
- AD0872927
Entities
People
- Bruno T. Plizak
Organizations
- Naval Air Warfare Center Warminster