SFCW Generator Alignment Techniques

Abstract

Depending on the design, synthesized-sweep SFCW generators often have phase discontinuities at certain intervals (such as 1 MHz) when sweeping over a wider band. In addition, when sweeping repetitively over a small interval (such as 100 kHz), the starting phase may not be coherent from one sweep to the next. Undesired phase discontinuities give rise to spurious spectral components and prevent application of MTI techniques. This report discusses modifications and adjustments for minimizing or avoiding phase discontinuities in SFCW exciters of the type first developed at Stanford University. The same approaches should be useful for other exciter designs as well. In addition, a novel oscilloscope display of wide applicability is described, which greatly simplifies both the measurement of phase coherence and the performance of corrective adjustments.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Oct 01, 1970
Accession Number
AD0878587

Entities

People

  • A. C. Phillips
  • P. Evans

Organizations

  • Stanford University

Tags

Communities of Interest

  • Energy and Power Technologies
  • Materials and Manufacturing Processes

DTIC Thesaurus Topics

  • Continuity
  • Difference Frequency
  • Discontinuities
  • Electronics Laboratories
  • Export Controls
  • Frequency
  • Frequency Dividers
  • Generators
  • Government (Foreign)
  • Intervals
  • Military Research
  • Signal Generators
  • Signal Processing
  • Sine Waves
  • Universities
  • Waveforms
  • Waves

Fields of Study

  • Physics

Readers

  • Radar Systems Engineering.
  • Systems Analysis and Design