Prime Item Fabrication Specification for Data Link Correlator-Processor, Shelter Mounted ES-96A.
Abstract
This specification establishes the requirements for manufacture and acceptance of a Data Link Correlator-Processor, Shelter Mounted, CI Number 343N831. The CI described herein is an air transportable and ground mobile shelter. The shelter is used to process, correlate, record, and display data from the data link receiver. The shelter shall be operable with an external temperature range of -30 F to +125 F, withstand a storage environment of -60 F to +160 F, withstand wind loads of 109 knots with shelter guyed (87 knots with shelter unguyed), and withstand ice loads equivalent to 2 inches of glazed ice. The calculated maximum weight of the shelter, payload, and transporter shall be 9955 pounds when the shelter is configured for transport.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 16, 1971
- Accession Number
- AD0891250
Entities
Organizations
- Goodyear Aerospace