SUU-13C/A Dispenser Intervalometer Development.
Abstract
The purpose of this intervalometer development program was to design, fabricate, test and qualify an intervalometer for use with the SUU-13C/A dispenser. Performance requirements included dispensing rates of 25, 50, 100 200, and 300 milliseconds with a tolerance of + or - 10 percent overall, a noncumulative step-to-time deviation of + or - 5 percent, and an input operating voltage of 18 to 30 volts dc. Ten intervalometers were qualified by completion of preliminary and final bench tests and environmental tests complying with the applicable portions of MIL-STD-810B. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1973
- Accession Number
- AD0910674
Entities
People
- Francis M. Cummings
Organizations
- Aerojet Rocketdyne Holdings