Hardness Program - EMP. EMP - RFI Protection MSR for Safeguard TSE Ground Facilities. Volume 3. Maintenance Items, Location Plans and Elevations, Design Drawings and Details Grand Forks Site.
Abstract
The SAFEGUARD GROUND FACILITIES and installed equipment have been made hard to the damaging effects of electromagnetic pulse (EMP) and radio frequency interference (RFI). This volume provides a guide for locating and describing the means of access to the EMP/RFI maintenance items in the Missile Site Radar and Firing Site complex (MSR/FSC) at Grand Forks. This volume fits into the total Protection Integrity Maintenance (PIM) planning effort conducted by USAEDH by providing the location and means of access to the maintenance items in the MSR/FSC, Grand Forks. (Author)