Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

Abstract

The United States Army conducted a survey of over 1700 fuel samples with the objective of evaluating the proposed limits for use by automatic light obscuration particle counters for the monitoring of aviation fuel cleanliness. The laboratory data collected supports the proposed ISO code limit, based on ISO 4406, of 19/17/14/13 limits for the 4m(c)/6m (c)/ 14m (c)/ 30m (c) size channels. The proposed limits were derived from 1.0 mg/L concentration levels for ISO12103-1 A1Ultrafine and ISO 12103-1 A2 Fine test dusts, and down to a 5 ppm free water contamination.