PFAS Emissions Measurement Methods Development and Emissions Characterization Study at National Response Corporation Alaska, LLC AFFF Contaminated Soil Thermal Treatment Facility
Abstract
This study successfully demonstrated the application of PSS to indicate overall quantitative measurement performance for targeted PFAS measurements for the modified EPA Method 0010 sampling train and associated analyses. A minimum PSS recovery of 70% and a maximum of 130% is typically required for EPAs isotope dilution emissions measurement methods. PSS recoveries averaged 100.3% and 70.3% for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) respectively. Moreover, there was no evidence of the PSS compounds migrating from the XAD-2 to the impingers during sampling, even in an extremely high moisture environment. It is because of these results EPA is able to proceed with the preparation of a formal test method for quantitative, targeted PFAS emissions measurements. This method is now identified as DRAFT Other Test Method (OTM) 45, a candidate EPA Test Method recommended for measurement of targeted PFAS compounds from stationary sources.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 31, 2019
- Accession Number
- AD1134823
Entities
People
- Brian Gullett
- Jeffrey V. Ryan
Organizations
- Environmental Protection Agency