Lubricating Oil Low Pressure Alarm Contact Maker. Clark Cooper Company - Exhibitor
Abstract
The subject contact maker was set up at this Laboratory in an air system, simulating service conditions, and closely observed while under test for the required number of operations. Particular attention was given to the operating point of the contact maker, throughout the test, to determine its suitable in maintaining the original predetermined setting. The usual tests for shock integrity, insulating resistance, dielectric strength, watertight integrity and operation at over pressures were conducted.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 08, 1935
- Accession Number
- AD1149318
Entities
People
- W. B. Roberts
Organizations
- United States Naval Research Laboratory