Test on Valve, Solenoid Operated, for Air Horns
Abstract
The modified solenoid operated valve, submitted under reference (c), resulted from comments under NRL letter, reference (b). It was set up at this laboratory in an air line, having a maximum pressure of 150 lbs. per square inch, and carefully observed while under test for compliance with the specifications, outlined in paragraph 17. Particular attention was given the operation of the valve under adverse conditions, such as lowering the solenoid voltage to 103.5 volts, at a frequency of 65 cycles, while applying an air pressure of 150 lbs. per square inch to the valve.