Report of Test on Wind Intensity and Direction Indicating Equipment
Abstract
Upon completion of tests for wind velocity versus anemometer speed, conducted by the Bureau of Standards, Washington, D.C. , the system, shown by Plates 4 to 15 respectively, was set up at this Laboratory and checked for conformance with the specifications, references (b) and (c). The order in which the tests were made is outlined therein under paragraph F-2.