Test on Master Speed Repeater Indicator Submitted by Pitometer Log Corporation

Abstract

The subject indicator, shown by Plates 1 to 4 inclusive, was set up at this laboratory and checked for conformance with the specifications, reference (b), in so far as applicable. The test was concluded with an inspection of the indicator to ascertain whether it complied with the specifications in the matter of materials, design and workmanship.