Test on Gun Firing Transformer, 200 V.A. Submitted by Jefferson Electric Company

Abstract

The subject transformer was set up at this Laboratory in standard test circuits, and its performance carefully checked to ascertain whether it was in strict accordance with the specifications, reference (b) in inspection of the transformer, relative to materials, design, workmanship and shock integrity, concluded the test.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Oct 23, 1936
Accession Number
AD1154856

Entities

People

  • J. S. Bryant
  • W. B. Roberts

Organizations

  • United States Naval Research Laboratory

Tags

DTIC Thesaurus Topics

  • Buildings And Structures
  • Inspection
  • Materials
  • Specifications
  • Standards
  • Transformers

Fields of Study

  • Physics

Readers

  • Electrical Engineering
  • Facility/Structural Engineering.
  • Systems Analysis and Design