Test on Salinity Indicator Equipment Submitted by Sperry Gyroscope Company
Abstract
The subject system, shown by Plates 1 to 4 inclusive, was set up at this laboratory in suitable test circuits and carefully checked for conformance with the specifications, reference (b). All test were made in order as specified, except that the vibration test was omitted and the 500-hour endurance test was shortened to 50 hours as requested by the Bureau in order to expedite the tests. The test was concluded with the usual inspection of the equipment to ascertain whether it complied with the requirements in the matter of materials, design and workmanship.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 28, 1937
- Accession Number
- AD1154901
Entities
People
- W. B. Roberts
Organizations
- United States Naval Research Laboratory