Retest of Style A Wire Wound Resistors (Grade 1, Class II) Submitted by the International Resistance Company
Abstract
Since these units are identical to those reported in reference (c) for improvement in the protective coating as stated in reference (d), they were tested only to determine the effects of humidity, that is the effect of salt water immersion and the strength of the finished units and of the ferrule securing after the immersion test. Data on other tests as required by specifications, reference (b), are included in reference (c) and are considered as applying to these units.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 26, 1938
- Accession Number
- AD1155939
Entities
People
- A. H. Taylor
- Robert B. Owens
Organizations
- United States Naval Research Laboratory