Test of Racon Midget Marine Amplifier Reproducer

Abstract

The unit was inspected for general construction, wiring, and workmanship. It was tested to determine the following: (a) Electrical power delivered to the reproducer unit with an a-c input of 1 volt. (b) The frequency characteristic of the acoustical output between 350-3500 c.p.s. with a constant input voltage. (c) Whether the unit is capable of continuous and satisfactory operation for a period of 24 hours. (d) The effect of excessive vibration. (e) The effect of atmospheric humidity. (f) The effect of extreme ambient temperatures. (g) The effect of shock.