Test on Wind Intensity and Direction Indicating Equipment Manufactured and Submitted by Henschel Corporation

Abstract

Upon completion of tests for wind intensity, versus indicated intensity, conducted by the Bureau of Standards, Washington, D. C., the system, shown by Plates 2 to 6, inclusive, was set up by this Laboratory and checked for conformance with the specification, reference (b). The order in which the tests were made is outlined therein under paragraph F-2.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jan 02, 1940
Accession Number
AD1159375

Entities

People

  • G. K. Hardesty
  • J. R. Coomes
  • J. S. Bryant
  • W. B. Roberts

Organizations

  • United States Naval Research Laboratory

Tags

DTIC Thesaurus Topics

  • Anemometers
  • Ball Bearings
  • Bearings
  • Corporations
  • Engineering
  • Friction
  • Materials
  • Navy
  • Specifications
  • Standards
  • Synchronous Motors
  • Transmitters
  • Wind
  • Wind Direction
  • Wind Direction Indicators
  • Wind Tunnel Tests
  • Wind Tunnels
  • Wind Velocity

Readers

  • Fault Tolerant Diagnosis of Black and White Balloon Isolation Tests Using ¥.