Blown-Fuse Transformers Submitted by R.C.A. Manufacturing Company, Camden, N.J.

Abstract

The sample transformers were set up at this Laboratory in a suitable test circuit as shown by Plate 2, where their performance was carefully observed for compliance with the specifications, reference (b) as modified by reference (c). An inspection of the sample to determine compliance in the matter of materials, design, and workmanship, concluded the test.