Test of M.F. Formica Submitted by the Formica Insulation Co.

Abstract

The dry and wet loss factors were determined by measurements made at 1000 kc in compliance with paragraph 2 of reference (d) and paragraph 6-1 of reference (f), and in accordance with A.S.T.M. standards on Testing Electrical Insulating Materials of December 1941. The wet loss factor was measured after the samples had been immersed in distilled water for 48 hours.