Test of Six Wire Wound Style a Fixed Resistors Submitted by Hardwick, Hindle, Inc.

Abstract

The test numbers used throughout this report, correspond to those of paragraph 13-1 of reference (b), and are distinguished by enclosure in parentheses. Complete tests were not conducted because these resistors failed in the salt water immersion test. The following tests were made: (1) Compliance with mechanical requirement of reference (b) including dimensions, workmanship and markings. (6) Resistance at 20 deg C. (9) Strength of finished resistor. (10) Power dissipation at a hot spot temperature of 275 deg C. (11) Resistance to thermal shock. (12) Momentary Overload. (13) Salt water immersion. (14) Strength of ferrule securing.