Abstract
This technical memorandum describes the IPIL testing conducted on a combined configuration that included the E-A-R (trademark) Classic (trademark) Earplug and the ComTac (trademark) V Headset. Testing included two test modes for the ComTac (trademark) V: passive and active. In all occluded conditions, the E-A-R (trademark) Classic (trademark) was in situ. Testing was completed in accordance with the ANSI standard S12.42-2010. All device samples were tested at the nominal levels of 160 and 170 decibel peak (dBP, re: 20 micropascals). A total of five samples were fitted to an acoustic test fixture two times each for a total of 10 trials per test level in both test modes. The mean and standard deviation (SD) IPIL values at 160 dBP were 53.1 (2.6) dB SPL for the passive mode, and 56.2 (3.5) dB SPL for the active mode. Results at 170 dBP showed mean (SD) IPIL values of 57.7 (1.4) dB SPL for the passive mode, and 59.8 (2.4) dB SPL for the active mode. These results suggest that the ComTac (trademark) V Headset, when functioning properly and fitted in combination with the E-A-R (trademark) Classic (trademark) earplugs can adequately protect against impulses below 180.0 dBP in both the passive and the active test modes.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 18, 2022
- Accession Number
- AD1175405
Entities
People
- Alexa H. Kolias
- Derek W. Schwaller
- Jeremy S. Federman
- Natalie Silvia
- Stephanie J. Karch
Organizations
- Naval Submarine Medical Research Laboratory