Insulating Material Submitted by Hartford Faience Company

Abstract

The wet loss factors were determined by measurements made at 1000 Kc, in compliance with paragraphs F-1, F-2a and F-2c of reference (e). Dry measurements were also made on the samples. The dry loss factors were calculated and included in this report.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jun 10, 1943
Accession Number
AD1175603

Entities

People

  • A. H. Taylor
  • J. E. Martin
  • W. B. Burgess

Organizations

  • United States Naval Research Laboratory

Tags

Communities of Interest

  • Advanced Electronics

DTIC Thesaurus Topics

  • Absorption
  • Dielectric Permittivity
  • Dielectric Properties
  • Dielectric Strength
  • Direction Finding
  • Electrical Measurement
  • Electron Tubes
  • Filter Paper
  • Frequency
  • High Voltage
  • Materials
  • Measurement
  • Moisture
  • Navy
  • Shock
  • Standards
  • Thermal Shock
  • Voltage

Readers

  • Acoustics.
  • Fault Tolerant Diagnosis of Black and White Balloon Isolation Tests Using ¥.
  • Reinforced Composite Materials

Technology Areas

  • Microelectronics
  • Microelectronics - Graphene