Preliminary Report on A Schering Bridge Method of Corona Detection in Cables

Abstract

The following is a preliminary report on the Naval Research Laboratory method for the detection of corona in solid dielectric cables. It does not incorporate any information on the simplified method, still in the research stage, of testing cables. In short, it describes the method heretofore used at the Naval Research Laboratory for the measurement of type approval samples, but does not represent the laboratory's final word on the optimum equipment for corona detection.