Investigation of RMA and NRL Transformer Test Chambers for Proposed Specification JAN-T-27
Abstract
The RMA standard transformer test chamber has serious defects which restrict its usefulness for temperature rise and overload measurements required by the transformer specification PRO-JAN-T-27. A proposed substitute chamber designed and constructed at this Laboratory is superior in the following respects: (a) the temperature distribution is more uniform (b) the size is much smaller (c) the weight is less (d) the heater power of consumption is less (e) the chambers can be stacked.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 27, 1946
- Accession Number
- AD1199690
Entities
People
- G. L. Anderson
- H. S. Robertson
Organizations
- United States Naval Research Laboratory