Performance of Infrared Optical Systems
Abstract
Experimental curves were obtained which indicate the relative resolving power of various optical systems for infrared radiation from a black body whose maximum output was a wavelength of approximately 8 microns. Spherical mirrors with and without Schmidt and Maksutov corrector plates were tested. It was found that if the field of view is less than ten minutes wide, a spherical mirror is nearly as good as the f/0.83 system with the rock-salt Schmidt plate which was tested.
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1947
- Accession Number
- AD1204315
Entities
People
- G. L. Harvey
Organizations
- United States Naval Research Laboratory