Solar Collector Thermal Power System. Volume 2. Development, Fabrication, and Testing of Fifteen Foot Heat Pipes
Abstract
Technical effort in the development of a 15-foot long primary heat pipe capable of transferring 6 kW of thermal power and its integration with the remaining components of a complete thermal train is presented. The effort comprised the design, fabrication, and testing of the heat pipe as an individual component and the integration and testing with the secondary heat pipe, the thermal energy storage unit, and a radiation heat transfer joint.
Document Details
- Document Type
- Technical Report
- Publication Date
- Nov 01, 1974
- Accession Number
- ADA000941
Entities
People
- Robert Richter
Organizations
- Xerox