Design and Fatigue Testing of Integral Armored Servo Actuator Modified Trunnion
Abstract
The program summarized by this report was conducted to design and establish the structural strength of a modified trunnion design for the integral armored servo actuator. The originally designed trunnion was found to have a fatigue strength below the mean strength level of comparable CH-54B parts as reported in USAAMRDL Technical Report 73-25. The design analysis and fatigue test data show that the modified trunnion is comparable in strength to the mean strength levels of the equivalent components on the production CH-54B helicopter.
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1974
- Accession Number
- ADA002069
Entities
People
- Kimberly M. Wood
- L. Moriarty
Organizations
- United Technologies Corporation