Results of Testing the AEDC 5-MW Segmented ARC Heater

Abstract

The results of testing a nominal 5-MW segmented (constrictor channel type) arc heater are presented. The heater was operated at chamber pressures up to 104 atm with power inputs to nearly 3 MW using air as the test gas. Bulk enthalpies ranged from about 7000 Btu/lb at 26 atm to 4500 Btu/lb at 102 atm. The nozzle exit flow was surveyed with null-point calorimeters and pressure and enthalpy probes. Performance comparisons are made between the segmented and Linde-type arc heaters. Detailed test and data summaries are presented. All testing was performed at the Arnold Engineering Development Center.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Dec 01, 1974
Accession Number
ADA002313

Entities

People

  • Dennis D. Horn
  • St. George A. Brown

Organizations

  • Arnold Engineering Development Complex

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Air Force
  • Arc Heaters
  • Boundary Layer
  • Calorimeters
  • Contracts
  • Electric Power
  • Energy
  • Engineering
  • Enthalpy
  • Flow Rate
  • Heat Flux
  • Instrumentation
  • Measurement
  • Power
  • Segmented
  • Silver Solders
  • Steady State

Fields of Study

  • Physics

Readers

  • Fluid Dynamics.
  • Plasma Physics.