Major Item Special Study (MISS), UH-1H Tail Rotor Hangers.
Abstract
Major Item Special Study (MISS) reports are performed on DA Form 2410 reportable components. These are time change items and certain condition change items selected because of high cost or need for intensive management. Basically, the MISS reports are concerned with analyzing reported removal data presented in the Major Item Removal Frequency (MIRF) report. The failure modes reported for each removal are examined and grouped into categories which are intended to clarify the intent of the data reporting. From this data, removal distribution can be plotted and an MTR (mean time to removal) can be calculated. The MISS reports then investigate possible cost savings based on total elimination of selected failure modes. These modes are chosen because of the percentage of failures they represent and/or because they appear to be feasible Product Improvement Program (PIP) areas.
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 01, 1974
- Accession Number
- ADA003263
Entities
Organizations
- United States Army Aviation and Missile Command