Surveillance Program Findings for Army MH-1A Reactor at End of Core 3

Abstract

Charpy-V and tensile test results for five surveillance capsules removed from accelerated exposure, vessel wall, and above-core locations in the ARMY MH-1A reactor are presented. The capsules were originally installed in the reactor prior to its initial startup. Neutron flux and fluence determinations from a vessel wall neutron flux monitor assembly are also presented.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1974
Accession Number
ADA003457

Entities

People

  • Charles Z. Serpan
  • Henry E. Watson
  • J. Russell Hawthorne

Organizations

  • United States Naval Research Laboratory

Tags

Communities of Interest

  • Ground and Sea Platforms

DTIC Thesaurus Topics

  • Abstracts
  • Assembly
  • Dosimeters
  • Dosimetry
  • Elements
  • Iron
  • Materials
  • Military Research
  • Neutron Flux
  • Pressure Vessels
  • Radiation
  • Radiation Effects
  • Stainless Steel
  • Surveillance
  • Tensile Properties
  • Yield Strength

Fields of Study

  • Physics

Readers

  • Aerospace Engineering
  • Electrical Engineering
  • Nuclear and Radiation Engineering.