Icing Tunnel Test - Hot-Film Anemometer.

Abstract

A limited test is reported of a Thermo-Systems Inc Series 1050 constant-temperature hot-film anemometer system in the Lockheed-California Company icing research tunnel to determine its suitability as a detector of discrete water droplets and liquid water content in natural and artificial icing clouds. It was determined that the hot-film anemometer was capable of recording individual but that the signal processing equipment required modification to prevent errors due to noise, saturation, and frequency response. Recommendations include improved signal processing electronics and precautionary procedures to enhance anemometer survivability.

Document Details

Document Type
Technical Report
Publication Date
Feb 01, 1974
Accession Number
ADA005044

Entities

People

  • Paul R. Bonin
  • Robert P. Jefferis

Tags

DTIC Thesaurus Topics

  • Anemometers
  • California
  • Communication Equipment
  • Detectors
  • Electronic Equipment
  • Electronics
  • Frequency
  • Frequency Response
  • Processing Equipment
  • Saturation
  • Signal Processing
  • Survivability

Readers

  • Aerospace Engineering
  • Fluid Mechanics and Fluid Dynamics.
  • Image Processing and Computer Vision.

Technology Areas

  • Microelectronics