Cross-Coupling in the SAFEGUARD System.

Abstract

Cross-coupling of EMP-induced electrical transients in the SAFEGUARD system has been divided into three broad categories: small enclosures, conduit runs, and cable spreading room. For the first two, models were constructed based on comparisons with available test data. From these models, a variety of cross-coupling results were calculated which can be applied directly to SAFEGUARD EMP analyses. The model parameters were chosen to be reasonable but conservative. Enough different situations are reflected in the calculated results so that most of the cross-coupling situations in the SAFEGUARD system are covered. The degree of sophistication of the models is consistent with the analyses performed for SAFEGUARD equipment/flowpath evaluations. The degree of cross coupling in the cable spreading room is obtained from test data taken at the SAFEGUARD North Dakota site.