Alert Attack Switch Isolation.
Abstract
The transients on the internal (to the facilities) portion of soft circuits due to their external EMP pickups can adversely affect the critical hardware performance either directly through introduction of perturbations to the power bus(es) they are connected to, or indirectly through cross-coupling to totally unrelated circuits which are in their physical proximity. The Alert Attack Switch (AAS) Ssystem disconnects external soft circuits, thereby providing protection to internal, critical subsystems from the EMP transients induced on external circuits. This memorandum presents a mathematical description relating the input (external) and output (internal) EMP transient, on a circuit across an activated (open) alert attack switch. From the results the internal transient can be computed adequately for any given external transient wave shapes. Results of calculations are also presented for external transients of the double exponential type with time constants of interest.